| Method | EPA Method 505 |
|---|---|
| Title | ANALYSIS OF ORGANOHALIDE PESTICIDES AND COMMERCIALPOLYCHLORINATED BIPHENYL (PCB) PRODUCTS IN WATER BYMICROEXTRACTION AND GAS CHROMATOGRAPHY |
| Abstract | Thirty-five mL of sample are extracted with 2 mL of hexane. Two UL of the extract are then injected into a gas chromatograph equipped with a linearized electron capture detector for separation and analysis. Aqueous calibration standards are extracted and analyzed in an identical manner in order, to compensate for possible extraction losses. |