| Method | EPA Method 8015A |
|---|---|
| Title | NONHALOGENATED VOLATILE ORGANICS BY GAS CHROMATOGRAPHY |
| Abstract | Method 8015 provides gas chromatographic conditions for the detection of certain nonhalogenated volatile organic compounds. Samples may be introduced into the GC using direct injection or purge-and-trap (Method 5030). Ground water samples must be analyzed by Method 5030. A temperature program is used in the gas chromatograph to separate the organic compounds. Detection is achieved by a flame ionization detector (FID). |
| CAS # | Compound Name |
|---|---|
| 60297 | Diethyl ether |
| 64175 | Ethanol |
| 78933 | Methyl ethyl ketone (MEK) |
| 108101 | Methyl isobutyl ketone (MIBK) |